Harrison Hydra-Gen Model 6.0/8.0/10.0 LPG Specifications

The generator shall be one (1) Harrison LPG Hydraulic Driven Generator rated at 6,000 watts, 25/50 amps, 120/240 VAC, 60Hz, 1-phase.

OR

The generator shall be one (1) Harrison LPG Hydraulic Driven Generator rated at 8,000 watts, 33/66 amps, 120/240 VAC, 60Hz, 1-phase.

OR

The generator shall be one (1) Harrison LPG Hydraulic Driven Generator rated at 10,000 watts, 82/84 amps, 120/240 VAC, 60Hz, 1-phase.

The generator shall be designed and assembled by a company with no less than 20 years experience in the manufacture of hydraulic driven generators.

The generator components shall be housed in a structural steel frame which affords protection to the components and provides a unitized mounting module.

The generator shall have top access to the oil filter, oil fill tube and electrical interface box.

The hydraulic oil reservoir shall include an oil level sight gauge visible from three sides; an oil temperature gauge; an oil fill cap; an oil filter and an internal venturi boost unit to provide positive pressure to the pump suction port.

The hydraulic oil reservoir shall be shipped attached to the structural steel frame. The hydraulic oil reservoir shall have an option to be remote mounted if required.

The generator shall have a cover consisting of NFPA approved diamond tread plate.

A meter package that provides the frequency, voltage and amperage of each leg shall be provided.

The generator shall not utilize electronic controls or a multiplex system to control the frequency.

The generator shall include a bypass solenoid to remotely turn the generator on/off with a 12 VDC signal.

The generator shall be a commercial type with a heavy-duty bearing and of brushless design to ensure low maintenance. No brushes or slip rings shall be allowed.

The generator and motor shall be close coupled and aligned using a Morse taper with a through bolt to secure the motor to the generator. No two (2) bearing generators shall be permitted.

The system shall be capable of producing the full nameplate power when driven from the vehicle PTO from idle to maximum engine speed.

The generator shall be able to be used while vehicle is either stationary or in motion.

The generator shall provide an option for a self sealing air intake to prevent re-circulation of exhaust air.

The generator shall provide a dedicated air intake duct for the alternator and a dedicated air intake duct for the heat exchanger. Both air intake ducts shall be located on the same side of the generator.

The hydraulic motor and pump shall be of axial piston design to provide low internal leakage and a high degree of frequency stability. Gear motors shall not be allowed.

The hydraulic pump shall match the system with the proper orifice, pressure compensator, and load sense settings to provide stable output regardless of engine rpm or electrical load demands. Use of electronics to control the flow shall not be allowed.

The system shall be capable of normal operations using a commonly available premium hydraulic oil; Mobile DTE series or equivalent. All fluid service points shall be in close proximity to the reservoir for ease of scheduled maintenance.

When properly installed, the system shall be warranted for a period of not less than two (2) years or 2000 hours, whichever should come first.

The generator shall be tested at the full nameplate rated load prior to shipping and the test report shall be included. The test report will document the generator's performance at various loads from no load to full load to ensure reliable power delivery at those loads.